Apr 17

In the application event log there is this error:

Fix – Event ID 10

Event Type: Error
Event Source: WinMgmt
Event Category: None
Event ID: 10
Date: 4/15/2012
Time: 2:12:43 AM
User: N/A
Computer: XYZComputername
Description:
Event filter with query “select * from HP_AlertIndication” could not be (re)activated in namespace “//./root/CIMV2” because of error 0x80041010.
Events may not be delivered through this filter until the problem is corrected.

For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp.

Solution:

1. On the managed node, open the wbemtest tool: C:\WINDOWS\system32\wbem\wbemtest.exe
2. Run : wbemtest
3. Connect to desired name space in this example root\cimv2
4. Select “Enum Instances”
5. Type: __EventFilter
6. Click OK
7. Select the instance then select “delete”

written by admin \\ tags: , , ,